JiZzJiZZ国产免费A_国产午夜成人AV在线播放_亚洲欧美在线观看一区二区_91久久久久精品无嫩草影院_欧美高清一区二区三区_欧美日韩国产码高清_亚洲精品国产电影_亚洲AV无码专区亚洲AV桃

您好,歡迎來到中美貿(mào)易網(wǎng)!請 |免費(fèi)注冊

產(chǎn)品展廳本站服務(wù)收藏該商鋪

上海阜立自動化科技有限公司

免費(fèi)會員
手機(jī)逛
上海阜立自動化科技有限公司
當(dāng)前位置:上海阜立自動化科技有限公司>>碳勢控制表>> 2604/2704 碳勢控制表

2604/2704 碳勢控制表

產(chǎn)品二維碼
參  考  價(jià):面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)
  • 產(chǎn)品型號:
  • 品牌:
  • 產(chǎn)品類別:溫度儀
  • 所在地:
  • 信息完整度:
  • 樣本:
  • 更新時(shí)間:2025-06-10 10:57:59
  • 瀏覽次數(shù):5
收藏
舉報(bào)

聯(lián)系我時(shí),請告知來自 中美貿(mào)易網(wǎng)

上海阜立自動化科技有限公司

其他

  • 經(jīng)營模式:其他
  • 商鋪產(chǎn)品:53條
  • 所在地區(qū):
  • 注冊時(shí)間:2014-08-20
  • 最近登錄:2025-06-10
  • 聯(lián)系人:崔先生
產(chǎn)品簡介

2604/2704 碳勢控制表

詳情介紹
2604/2704 碳勢控制表

2604/2704 碳勢控制表功能說明


Carburising

When Mild steels or certain low carbon steels are heated at temperatures above 900oC in a carbon rich atmosphere, the surface of the steel absorbs carbon by diffusion. The depth of carbon enrichment depends on the time and temperature of the treatment known as carburising. The presence of carbon in the steel causes a change in its physical properties. Accurate control of both temperature and carbon potential are needed to achieve the required profile of carbon enrichment.

Zirconia Sensor Theory

The Zirconia probe generates a millivolt signal based on the ratio of oxygen concentration between the reference airside of the probe (outside the furnace) and the amount of oxygen actually inside the furnace. Temperature is measured using a built in thermocouple at the tip of the probe. Together, these signals are used by the 2604 zirconia function block to calculate the actual percentage of carbon in the furnace atmosphere. The 2604 oxygen probe interface is compatible with most commonly used zirconia probes.

2604 Integrated Furnace Controller

Synchronised temperature/carbon profiles

Automatic probe cleaning

Furnace sooting alarm

Probe deterioration alarm

Temperature control of quench










A 2604 three loop controller is used to control both furnace temperature, carbon potential and quench. In many batch furnace applications a setpoint programmer is used to generate temperature and carbon profiles which are synchronised to a common time base.

Furnace Temperature Control

Although the sensor input of the temperature loop can come from the zirconia probe, it is more common for a separate thermocouple to be used. The heat control output can either be connected to gas burners or thyristors. In some applications a cooling output may also be connected to a circulation fan or an exhaust damper.

Furnace Atmosphere control

In atmosphere loops the controller increases the carbon potential by opening a solenoid valve which allows a carburising gas (ie propane) to enter the furnace. Conversely, to decrease the carbon potential, air or nitrogen is introduced into the furnace. Automatic probe cleaning functions ensure that the reading is accurate, whilst probe health and sooting alarms warn of a deterioration in the probes performance.

Quench Temperature Control

Steel parts are rapidly cooled (Quenched) from around 850oC to obtain the desired hardness, strength or toughness. Depending on the material being treated, the quench medium is usually oil or water. The quench control loop maintains the quench bath at the desired temperature and provides a quench timer facility.

Sooting Alarm

As well as alarms on the temperature and carbon potential in the furnace the 2604 can trigger an alarm, when the atmospheric conditions are such that carbon will be deposited as soot on all surfaces inside the furnace, including the workpiece. Avoiding sooting protects the furnace lining, maintains the accuracy of the zirconia probe and stops formation of a soot barrier on the workpiece which can prevent carbon diffusion.

Automatic Probe Cleaning

The 2604 has a probe clean and recovery strategy that can be programmed to occur between batches or manually requested by an operator. A short blast of compressed air is used to remove any soot and other particles that may have accumulated on the probe. Once the cleaning has been completed the time taken for the probe to recover is measured. If the recovery time is too long this indicates that the probe is ageing and replacement or refurbishment is due. During the cleaning and recovery cycle, the %CP reading is frozen thereby ensuring continuous furnace operation.

Enriching Gas Correction

A gas analyser can be used to determine the CO concentration of the enriching gas. If an analogue output is available from the analyser, it can be fed into the 2604 to automatically adjust the calculated % carbon reading. Alternatively, an operator may enter this value manually.


上一篇: 歐陸 3204 溫度控制表
下一篇: 歐陸3216溫度控制器
同類優(yōu)質(zhì)產(chǎn)品

在線詢價(jià)

X

已經(jīng)是會員?點(diǎn)擊這里 [登錄] 直接獲取聯(lián)系方式

會員登錄

X

請輸入賬號

請輸入密碼

=

請輸驗(yàn)證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
JiZzJiZZ国产免费A_国产午夜成人AV在线播放_亚洲欧美在线观看一区二区_91久久久久精品无嫩草影院_欧美高清一区二区三区_欧美日韩国产码高清_亚洲精品国产电影_亚洲AV无码专区亚洲AV桃